Home > Warning Error > Warning Error Writing Vtoc. Label Failed

Warning Error Writing Vtoc. Label Failed

Please type your message and try again. 12 Replies Latest reply: Nov 16, 2006 10:12 PM by JasonBailey metas not visible to host in cluster environment diskextender Nov 8, 2006 10:51 What bugs me is that the procedure worked fine on EVA array. The wierd thing is that we were able to see those metas a while ago. If I try to write the label I get: Warning: error writing VTOC. http://maxspywareremover.com/warning-error/warning-error-writing-vtoc-warning-no-backup-labels-label-failed.php

Re: metas not visible to host in cluster environment GlenH Nov 8, 2006 3:39 PM (in response to diskextender) DX,Have you labelled the device using format ? Re: metas not visible to host in cluster environment diskextender Nov 10, 2006 5:26 AM (in response to owen) Did you check whether the metas are actuallyRead/Write?symdev list should show RW, Please fill all the fields. Already a member?

For some reason when I tried to Autoconfigure the LUN on Clariion format would refuse to replace the VTOC, coming back with the following error: Continue labelling disk? Could you recommend what should be done (what commands to run) from the Solaris host side to clear PR? For seagate drives, the easiest way to do this is to download seatools enterprise utilities, stick a fibre card (ie: lp8000 or similar) in a pc, and use it to reformat chukcha2 posted Sep 24, 2016 ASUS A88XM-A on-board video issue GalacticDad posted Sep 15, 2016 three screen setup with the gtx 650 hassan123 posted Sep 2, 2016 Dark spot/residue on...

Thanks for the hint. > I have a bunch of non-recongnizable FC drives from e-bay, 520 byte sectors. > I think they came from AS400's or Hitachi something. > I know A Seagate ST336704FC is listed as a disk compatible with the Sun Blade 1000. Login with LinkedIN Or Log In Locally Email Password Remember Me Forgot Password?Register ENGINEERING.com Eng-Tips Forums Tek-Tips Forums Search Posts Find A Forum Thread Number Find An Expert Resources Jobs Until now, I have been doing this on HP EVA array.

Sun's format couldn't hack it, sformat worked like a champ. Please turn JavaScript back on and reload this page. However, if you choose not to continue with 1-Touch recovery immediately and wish to perform a backup (or any other task), then: Delete the Base/certificates folder on the client, and Restart other Adams Aug 29, 2004 Bad Magic number in disk label Reed, Nov 6, 2005, in forum: Sun Hardware Replies: 6 Views: 19,476 CJT Nov 7, 2005 Can read/open disk label/boot device.

Not ready error during read ASC: 0x4 ASCQ: 0x3 Warning: error reading backup label. Sign up now! yesWarning: error writing VTOC.Warning: no backup labelsWrite label failedEven if I try to format the LUN using format -e and select SMI as the label then also I get the same But this is the only system I have at home with a > FC disk > interface, and I can't get NetBSD or OpenBSD to boot on this system, > so

I did not know about blastwave.org, but now I do. http://www.motherboardpoint.com/threads/how-to-write-a-sun-disk-label-on-non-sun-disk.160180/ Solaris won't install. If I do "prtvtoc /dev/rdsk/c1t1d0s2" I get: prtvotc: /dev/rdsk/c1t1d0s2: Unable to read Disk geometry errno = 0x5 WARNING: /[email protected],60000/SUNW,[email protected]/[email protected],0/[email protected],0 (ssd1): Corrupt label; wrong magic number Now when I run format, for Continue?

Report Abuse Like Show 0 Likes (0) 8. navigate here I have a Sun Blade 1000 I got from ebay without a disk, and a Seagate ST336704FCV FC disk. Makes for very confused and frustrated SAN admins calling in So the solution to remove the PR was to remove the PER bit from the device, which is not a great I have a bunch of non-recongnizable FC drives from e-bay, 520 byte sectors.

FORMAT MENU: disk - select a disk type - select (define) a disk type partition - select (define) a partition table current - describe the current disk format - format and Type of disk: We have 3 quorum devices assigned to both systems, several 2gb mirrored metas and several 34gb mirrored metas (all seen by both systems). Any hints? Check This Out But I do not think I should have to manually zero out VTOC to write a new one, when connected to Clariion.

From To Subject Message Cancel Please wait... Talk With Other Members Be Notified Of ResponsesTo Your Posts Keyword Search One-Click Access To YourFavorite Forums Automated SignaturesOn Your Posts Best Of All, It's Free! I just brought up a 70gig FC drive >>that needed reformatting to 512 byte sectors- probably out of some >>horrible EMC box.

y Warning: error writing VTOC.

Otherwise, the client will not be able to boot off the network because both servers will respond to the client?s RARP request. Dell Technologies© 2016 EMC Corporation. G View solution in original post 0 Kudos Reply 7 Replies what is the version of OS & Gaurav_S Moderator Trusted Advisor Certified ‎06-06-2012 01:57 AM Options Mark as New Bookmark I just brought up a 70gig FC drive >> that needed reformatting to 512 byte sectors- probably out of some >> horrible EMC box.

are you able to read the VTOC ? # prtvtoc /dev/rdsk/c0t500009740800B55Dd42s2 how does the split of luns happened ? & how are these luns presented here ? you can perform a cleanup by following link: http://www.symantec.com/docs/TECH78463 If not working, probably restart the server with reconfig option would be my last go.... Join Us! *Tek-Tips's functionality depends on members receiving e-mail. http://maxspywareremover.com/warning-error/warning-error-writing-vtoc-warning-no-backup-labels-in-solaris.php Thanks Robert , Mar 18, 2007 #1 Advertisements Trinean Guest Does probe-scsi see the ST336704FCV from the ok> prompt?

If a client's backup completed successfully and is somehow failing to boot, be sure to check the sr.log on the 1-Touch server for any warning. When you go to label > the disk it will give you the option of either SMI or EFI. Once sformat has a label on it, regular format will work fine. >> >>Gregm >> > > > I will try this. For DHCP clients, run the following commands: ./rm_install_client ./rm_install_client ./rm_install_client -f Sometimes, the RARP, bootparams and tftp daemons fail to re-read network information pertaining

I can see all my diskgroups and EMC Replication Manager can now mount all replicated copies Thanks for the help all 0 Kudos Reply Contact Privacy Policy Terms & Conditions Robert , Mar 19, 2007 #4 Chris Lawson Guest wrote: > How do I use Solaris to write a Sun disk label on a non-Sun disk? > > I have The default partition for the disk is: a 100% "SOLARIS System" partition Type "y" to accept the default partition, otherwise type "n" to edit the partition table.yformat> p PARTITION MENU: 0 Formatting cannot be interrupted.

However now when I run the Solaris FORMAT command the illegal device entires are missing Checking why SF is not detecting devices now The BCV /Split is managed by c1t3d0 /[email protected],700000/[email protected]/[email protected],04. no checking for EMX/OS2 environment... Troubleshooting - 1-Touch for Solaris The following section provides information on some of the troubleshooting scenarios related to 1-Touch Recovery: Problem or Error Solution The client is unable to boot.

Red Flag This Post Please let us know here why this post is inappropriate. I'm unable to label a disk - getting the error "Warning: error writing VTOC - Label failed". c1t0d0 /[email protected],700000/[email protected]/[email protected],01. When you go to label > the disk it will give you the option of either SMI or EFI.

You may get this error during phase 2 of 1-Touch recovery. cistec posted Aug 14, 2016 Power Problem Building New... Choose SMI. Please type your message and try again.

:(){ :|:& };: Home Useful links About Contact unixpowered.com Solaris 10 VTOC weirdness on EMC Clariion Array I was doing some Solaris 10 8/07 testing with EMC Clariion CX4-960 array. If you continue with the subsequent phases of 1-Touch recovery, this will not be a problem.