Re-test Drive 137 Relocated Sector Sector Relocated. It's definitely going out on ya. Replace Drive 219 Drive Cable Error Failure during cable test. Re-Test Drive 7 SMART Offline Immediate Command Failure Self-Monitoring, Analysis, and Reporting Technology (SMART) Offline Immediate command failed. weblink

Replace the drive if the error repeats. Replace the drive if the error repeats. There were too many errors found on this drive to be repaired. The automatic repair feature can attempt a repair if possible. navigate to these guys

No Errors 101 Unknown Error An unknown error has occurred during testing. Retest after checking the connections. Check Floppy and use appropriate diagnostic utility 209 Self Test Failed To Run SMART Self Test failed to start when executed.

This may be due to a defect with the drive or the drive may not have responded properly due to a bad connection. There were too many errors found on this drive to be repaired. Kindly help if anyone has faced this issue or have any idea on the resolution.  Is it a firmware issue. Retest the drive.

If ECC occurs, use Data Lifeguard for additional error correction. Status code = 06 (Failed servo and/or seek test element), Failure Checkpoint = 97 (Unknown Test) SMART self-test did not complete on drive 2! Retest after checking the connections. Hard Drive Diagnostics Tools and Utilities (Storage) - TACKtech Corp.

not macshows nice picbigCaseafro engeneeredView all hide details Reply wats this (13 items) CPUMotherboardGraphicsRAMfaster then an amdgigerbyte er gtfointernalgood ramzHard DriveOSMonitorPowerthere hardha! Replace the drive if the error repeats. Check Floppy and use appropriate diagnostic utility 207 Critical Resource Error Unable to locate and/or use a system resource (e.g. - printer). Re-test Drive 137 Relocated Sector Sector Relocated.

Please ensure that you are not loading any other DOS level files from the floppy prior to running diagnostic utility. Re-test Drive 148 Not Selected Drive not selected. Re-test Drive 213 2-9 DAM Errors Data Address Mark (DAM) 2-9. SERVO is data on track location.

In the first SMART log you have 616 reallocateds, and in the second log you have 661. have a peek at these guys Flag Permalink Reply This was helpful (0) Back to PC Hardware forum 3 total posts Popular Forums icon Computer Help 51,912 discussions icon Computer Newbies 10,498 discussions icon Laptops 20,411 discussions It may also happen when the wrong version of diagnostic utility is used. Retest after checking the connections.

Replace Drive 210 Self Test Incomplete SMART Self Test failed to complete (e.g. -- timed out). Replace the drive if the error repeats. This is the pretest initialization code which indicates a drive is ready to be tested, but has not yet been tested. check over here Re-Test Drive 8 Read Sector Failure A Read command during the test has failed.

Replace the drive if the error repeats. This may be an anomaly or a defect with the drive. Check cable and retest.

Twice it has just as spontaneously healed itself after a week or so (because I crossed my fingers?) as I requested an RMA.You might try warm or cold re-boots with different

Replace Drive 223 Errors Repaired Errors found, but have been repaired successfully. Replace Drive If an error code is encountered that is not in the list above, please Contact Us for additional troubleshooting. ECC is a hardware correction technique that corrects errors. Re-test Drive 206 Memory Allocation Error Unable to allocate memory for program structures.

The drive has not responded to the SMART test request. Re-Test Drive 10 Set File Pointer Error A SetFilePointer command during the test has failed. Between two to nine errors have been detected. http://maxspywareremover.com/western-digital/western-digital-error-status-code-007.php and than i decided to make low level format .

I took the connector off and installed it in via SATA cable and power cable and installed it in one of  the open bays in my computer and does not  recnize This error is most likely an internal malfunction of the drive and not related to the condition of the cables etc. Re-Test Drive 20 Failed to Delete Partitions A Device I/O Control command during the test has failed. Replace the drive if the error repeats.

sorry about late reply wasn't home for a while Top rowan194 Post subject: Re: Wd scorpio Blue 320 is going badPosted: September 16th, 2009, 7:46 Joined: September 12th, in a way that is recoverable, so I just do a cascade file copy & exports.Good luckBackup & Security are a perpetual chore. The Identify Drive Command has not received an acceptable response from the drive. Data sent between the host computer and the drive has been corrupted.

It's not a good idea to open up the drive it will void the warranty. Replace Drive 584 Diag Command Error During a Quick Test, the sefl-test failed.