Home > What Is > What Is Sysplanar Error In Aix

What Is Sysplanar Error In Aix

Contents

Solve problems - It's Free Create your account in seconds E-mail address is taken If this is your account,sign in here Email address Username Between 5 and 30 characters. Romeo Ninov replied May 8, 2013 Use errpt -a to get the entire error, usually inside the cause is explained. myself4unix replied May 8, 2013 Looks like you need to open a Hardware PMR with IBM. however diag frequently can't run correctly on a running system because the devices it wants to test are in use.

How many copies of the error do you see in the errpt? And if some APARs exist about such problem apply fixes or next version. Thanks in advance. Log in to reply.

Power/cooling Subsystem Unrecovered Error, Bypassed With Loss Of Redundancy

You may also copy the file system from one place to… Unix OS Live Patching for the Solaris 9 Operating System Article by: ganjos Introduction Regular patching is part of a I have seen that many times on my frames. This Forum is not the sort of place for help: 1) The forum is too slow for an answer 2) Support has the tools to investigate the error report and sense

If not better contact IBM support Help the community by fixing grammatical or spelling errors, summarizing or clarifying the solution, and adding supporting information or resources. Sign in to make your opinion count. IBM Watson 630,700 views 7:54 New POWER7 workload optimizing systems - Duration: 2:23. Ibm Support Has there been such a reset?

Sign in to add this video to a playlist. Platform Firmware Predictive Error But If it's production lpar and this kind of error will repeat I will call support. This can be caused by an unexpected shutdown (power failure) to the system, or it really could be that a power supply/fan has blown. http://unix.ittoolbox.com/groups/technical-functional/ibm-aix-l/bfe4c025-p-h-sysplanar0-undetermined-error-5188751 Anyway, there is no way around calling IBM service (asap)!

Refer to the system service documentation for more information. Additional Words: 2-91FF0002 3-01200000 4-00000000 5-00000000 6-00000000 7-00000000 8-00000000 9-00000000 Possible FRUs: Priority: M Maintainence Procedure: IQYRISM Select all Open in new All rights reserved.Unauthorized reproduction or linking forbidden without expressed written permission. BFE4C025 P H sysplanar0 Undetermined Error sanaulla ahmed asked May 8, 2013 | Replies (10) Dear All, In one of my IBM p550 server giving Error (BFE4C025 P H sysplanar0 UNDETERMINED You might have a critical error and need hardware support working on your problem.

Platform Firmware Predictive Error

Join your peers on the Internet's largest technical computer professional community.It's easy to join and it's free. http://www.tek-tips.com/viewthread.cfm?qid=443862 In the worst case it could be that the Bulk Power Regulator (BPR) or one of BPCs has bitten the dust, but I don't think so. Power/cooling Subsystem Unrecovered Error, Bypassed With Loss Of Redundancy Open a hardware call with IBM and have them replace the memory module and you'll be fine again. B181f126 Additional Words: 2-03400000 3-00000007 4-00000000 5-00000000 6-00000000 7-00000000 8-00000000 9-00000000 Possible FRUs: Priority: M FRU: SVCDOCS Location: n/a errpt -j BFE4C025 LPAR IDENTIFIER TIMESTAMP MMDDhhmmYY T C RESOURCE_NAME DESCRIPTION SIEGFRID BFE4C025

And if you have an IBM service contract you can submit this information. Loading... Do other lpars on the same frame show similar errors ? Reason: Use code tags, thanks. Remove advertisements Sponsored Links lo-lp-kl View Public Profile Find all posts by lo-lp-kl #2 08-03-2009 borek Registered User Join Date: Ba090007

Sign in 1 0 Don't like this video? Kind regards zxmaus Remove advertisements Sponsored Links zxmaus View Public Profile Find all posts by zxmaus #6 08-06-2009 lo-lp-kl Registered User Join Date: Jul 2004 Last Activity: 18 Logged Print Pages: [1] Go Up « previous next » AIX, Linux and POWER Portal » Hardware » Power4 » UNDETERMINED ERROR in p 650 server Design By SMFSimple.com SMF raja ismail replied May 8, 2013 Hi Sana Please check with motherboard Regards, Is Top Best Answer 0 Mark this reply as the best answer?(Choose carefully, this can't be changed) Yes

You're now being signed in. No spaces please The Profile Name is already in use Password Notify me of new activity in this group: Real Time Daily Never Keep me informed of the latest: White Papers You might have a critical error and need hardware support working on your problem.

If a function 22 was not performed, or if SRC word 3 is not 0007, look for other serviceable errors which occurred at same time frame.

Detail Data PROBLEM DATA 0644 00E0 0000 05DC 8E00 8E00 0000 0000 0000 0000 4942 4D00 5048 0030 0100 DD00 2009 0803 2050 1346 2009 0803 2050 1387 4500 010A 0000 RE: Sysplanar0 MoshiachNow (IS/IT--Management) 9 Jan 03 10:14 Hi,3.1Diagnosing the errlogRun: diag -> Diagnostics routines -> Problem determination This selection tests the system and analyzes the error log if one is crystalwizard replied Dec 11, 2006 >Running diag on a running system should not cause any problems. All rights reserved.

By joining you are opting in to receive e-mail. Show more In your opinion, how accurately does YouTube count the number of dislikes on a video?Thanks! newaxis aix 1,738 views 6:52 PowerBasics Install AIX from CD/DVD - Duration: 8:24. Add to Want to watch this again later?

CONTINUE READING Join & Write a Comment Already a member? Check the system for error lights on the power supplys and if necessary replace the faulty unit. siegfrid:[/]# errpt -aD -s 0302090007 -e 0302110007 | more LABEL: SCAN_ERROR_CHRP IDENTIFIER: BFE4C025 Date/Time: Fri Mar 2 10:55:30 WET 2007 Sequence Number: 205 Machine Id: 00C7669C4C00 Node Id: siegfrid Class: H If SRC word 3 is 0007, then a user may have initiated a function 22 prior to the operating system completing the IPL.

Join our community for more solutions or to ask questions. In this video, we show how to load the export from S3 into a DynamoDB table. mask728 asked Dec 11, 2006 | Replies (2) Hi, i have started getting this error for the past couple of days. Nigel Griffiths 8,169 views 8:11 2014 12 11 HMC V8 - Duration: 1:39:58.

http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/iphb5/f22msdc.htm No indication of a hardware problem or any need to call support nagger. Loading... wmp 0 Featured Post Find Ransomware Secrets With All-Source Analysis Promoted by Recorded Future Ransomware has become a major concern for organizations; its prevalence has grown due to past successes achieved The diag came up with this:A PROBLEM WAS DETECTED ON Thu Jan9 10:56:37 EST 2003801014The Service Request Number(s)/Probable Cause(s)(causes are listed in descending order of probability):2BA00000:Refer to the Error Code to

jaekoo cho 65,972 views 6:48 HUGE SECURITY FLAW in Google Earth/Maps - Youtube screennames return LOCATION + Mobile # - Duration: 13:42. I'm also new to the forum and it's good to be here.I love the site already. About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Try something new! Toolbox.com is not affiliated with or endorsed by any company listed at this site.

Please provide me with steps and commands (if needed) to check/resolve this issue. Diags show the SRC, B700 F104, look it up here: http://publib.boulder.ibm.com/infocenter/eserver/v1r3s/index.jsp?topic=/ipha6/refcodelist.htm Operating System error Platform Licensed Internal Code terminated a partition. Tell us more in a follow-up survey.Take surveyVery inaccuratelyVery accurately Language: English Content location: United States Restricted Mode: Off History Help Loading... KernelTraining.Com 24,190 views 59:20 IBM PowerLinux - Linux installation quick start with a graphics card - Duration: 7:52.